Temperature Range Shoring fluid (litres)  Water (litres)  Proportion
Fluid / Water
Greater than 0°C  10 30 1:3
C 20 20 1:1 20 20 1:1
Less than -10°C 40 0 N/A
Approx. Unit Weights (kg)
Empty 100
Full 150
Maximum Delivery Pressure 
Flow (ram out)  2176 Psi (150 bar)
Return (ram in) 2176 Psi (150 bar)

    This 110V, 32A Electric Shoring Pump (for use with Shoring Fluid) is intended for use on sites where conventional combustion engine pumps are not permitted. ALWAYS CHECK SUITABILITY OF THIS PUMP for the environment in which you are working.

    This unit requires a minimum power supply of a 7kVA (32A) generator which can be obtained from Brandon Hire Station (0345 604 5337).

    The pump can also be used in conjunction with the Instagrid Mobile Power Supply. For details on use of the Instagrid, see the relevant user guide which can be downloaded from the Groundforce Technical Library.

    110V Electric Shoring Pumps are intended for use with larger double acting (expanding and retracting) equipment such as hydraulic struts where large fluid volumes are involved. They are also ideal for the installation of multiple braces where the quick release hose connections speed up the installation process. The motor is rated at IP54, so shower proof only: do not submerge or power wash. Note: Always verify the pump's suitability for your specific work environment.